Broadcast Products
Plug-In Units for LT 443D
LT 443D-GLA Genlock Unit
GENERAL
This unit provides genlock capability to lock the LT 443D mainframe with the external reference signal, and three independent black signal generators.
The NTSC/PAL black burst signals, Principal 20 types of HDTV analog tri-level sync signal formats, and 525p/625p analog sync signals can be used as an external reference signal.
The following black burst signal formats can be selected.
For NTSC/PAL system, black burst signal with field reference pulse is provided. For NTSC system, black burst with 10-field sequence identification conforming to the SMPTE 318M standards is provided.
The instrument continues operation since the flywheel mode is provided even if the external reference signal is accidentally removed in genlock mode. By logging the genlock status, the time can be obtained when the external reference signal is removed. The log information can be stored on the CF CARD.
The genlock timing can be adjusted for the entire color frame range when the NTSC/PAL black burst signal is applied; entire frame range when the HDTV analog tri-level sync signal is applied.
Three black burst signal output systems with selectable formats are available as follows:
For NTSC/PAL system, standard black burst signal and black burst signal with field reference pulse are provided. For NTSC system, black burst signal with 10-field sequence identification conforming to the SMPTE 318M standards, 525p/625p analog sync signal, and HDTV analog tri-level sync signal are provided.
The format and output signal timing of each output can be respectively set. The black signal timing can be adjusted for the entire color frame range when the NTSC/PAL black burst signal is applied; entire frame range when the HDTV analog tri-level sync signal is applied.
The NTSC/PAL black burst signals, Principal 20 types of HDTV analog tri-level sync signal formats, and 525p/625p analog sync signals can be used as an external reference signal.
The following black burst signal formats can be selected.
For NTSC/PAL system, black burst signal with field reference pulse is provided. For NTSC system, black burst with 10-field sequence identification conforming to the SMPTE 318M standards is provided.
The instrument continues operation since the flywheel mode is provided even if the external reference signal is accidentally removed in genlock mode. By logging the genlock status, the time can be obtained when the external reference signal is removed. The log information can be stored on the CF CARD.
The genlock timing can be adjusted for the entire color frame range when the NTSC/PAL black burst signal is applied; entire frame range when the HDTV analog tri-level sync signal is applied.
Three black burst signal output systems with selectable formats are available as follows:
For NTSC/PAL system, standard black burst signal and black burst signal with field reference pulse are provided. For NTSC system, black burst signal with 10-field sequence identification conforming to the SMPTE 318M standards, 525p/625p analog sync signal, and HDTV analog tri-level sync signal are provided.
The format and output signal timing of each output can be respectively set. The black signal timing can be adjusted for the entire color frame range when the NTSC/PAL black burst signal is applied; entire frame range when the HDTV analog tri-level sync signal is applied.
Specifications
| Loop-Through Input | |||||||||||||
| Input
Configuration |
BNC connector,
75 |
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Return Loss | |||||||||||||
| Reference Input Signal | HDTV tri-level sync signal
conforming to SMPTE 240M/274M/296M standards 525p/625p analog sync signal conforming to SMPTE 293M/ITU-R BT 1358 standards NTSC black burst signal conforming to EBU N14/SMPTE RP-154/SMPTE 170M/SMPTE 318M standards PAL black burst signal conforming to ITU-R BT. 470-6 standards |
||||||||||||
| Reference
Input Signal Level |
HDTV: Positive polarity:
300 mV, Negative polarity: -300 mV 525p/625p: -300 mV NTSC: -286 mV PAL: -300 mV |
||||||||||||
| Maximum Input Level | |||||||||||||
| Operating
Input Level Range |
|||||||||||||
| External Lock Range | |||||||||||||
| Jitter | |||||||||||||
| Operation Modes | Five modes are selectable. Internal mode: INTERNAL
|
||||||||||||
| Genlock
Timing Variable Range |
H-PHASE (FINE): Covers between H-PHASE (COARSE) steps. H-PHASE (COARSE): Resolution: 0.0741 V-PHASE: Resolution: 1 line F-PHASE: Up to (Variable range depends on the input signal format.) Resolution: 1 frame (When NTSC black burst is applied, the coincident point of line 4 of the PAL and line 1 of the HDTV is handled as a reference. When PAL black burst is applied, the coincident point of line 1 of the PAL and line 1 of the HDTV is handled as a reference.) |
||||||||||||
| BLACK1/BLACK2/BLACK3 | |
| Format |
HDTV tri-level
sync signal conforming to SMPTE 240M/274M/296M standards 525p/625p analog sync signal conforming to SMPTE 293M/ITU-R BT 1358 standards NTSC black burst signal conforming to EBU N14/SMPTE RP-154/SMPTE 170M/SMPTE 318M standards PAL black burst signal conforming to ITU-R BT. 470-6 standards |
|---|---|
| Sync
Level (into 75 Ω ) |
HDTV: Positive polarity:
300 mV Negative polarity: -300 mV 525p: -300 mV 625p: -300 mV NTSC: 40 IRE PAL: -300 mV |
| Blanking Level | 0 mV |
| Rise and fall times | HDTV: 54 ns 525p: 70 ns 625p: 100 ns NTSC: 140 ns PAL: 200 ns |
| Horizontal Sync Width | 1125-Line: Positive polarity:
593 ns Negative polarity: 593 ns 750-Line: Positive polarity: 539 ns Negative polarity: 539 ns 525p: 2.35 625p: 2.35 NTSC/PAL: 4.7 |
| Vertical Sync Width | HDTV: 5H 525p: 6H 625p: 5H NTSC: 3H PAL: 2.5H |
| Output Impedance | 75 |
| Output Connector | BNC |
| Number of Outputs | 1 each |
| Timing Variable | H-PHASE: Up to Resolution: Variable in 1 dot steps (54 MHz, 74.25 MHz, or 74.25/1.001 MHz converted into clock frequency) V-PHASE: Up to Resolution: Variable in 1 line steps F-PHASE: Up to (depends on the input signal format.) Resolution: Variable in 1 frame steps |
| Environmental Conditions | |
| Operating Temperature Range | 0 to 40 °C |
|---|---|
| Operating Humidity Range | |
| Spec
Guaranteed Temperature Range |
10 to 35 °C |
| Spec
Guaranteed Humidity Range |
|
| Operating Environment | Indoor use |
| Operating Altitude | Up to 2,000 m |
| Overvoltage Category | I |
| Pollution Degree | 2 |
| Power Source | Supplied by the LT 443D mainframe |
|---|---|
| Dimensions | 79 (W) x 41 (H) x 371 (D)
mm (excluding projections) |
| Weight | Approx. 0.5 kg |